Full inverter multi-purpose outdoor unit for use in 4-pipe systems for the simultaneous production of chilled and hot water in two independent hydronic circuits. These units are able to simultaneously satisfy the demand for hot and cold water through a system that does not require seasonal switching and is therefore a valid alternative to traditional plants with chiller and boiler. Each circuit works with a variable speed drive semi-hermetic screw compressor using R513A, two shell and tubes heat exchangers and a source side coil heat exchanger shared by both circuits. The cold side shell and tube heat exchanger acts as an evaporator for the production of cold water, while the hot side shell and tube heat exchanger works as a condenser for the production of hot water. The source side auxiliary finned coil works as either condenser or evaporator as required by the loads.

Versions

  • CA – Class A of efficiency
  • SL-CA – Super Low noise version, Class A of efficiency
  • XL-CA – eXtra Low noise version, Class A of efficiency
EUROPE CEPEDUDT AS1210 50 Hz

 

Features

  • UNIQUE PROPOSAL
    Unit designed to satisfy the cold and the hot side requirements simultaneously, for 4-pipe systems without any particular operation mode setting
  • ENERGY SAVING
    Energy saving guaranteed by the advanced operation’s logic. The best operation mode is set completely automatically and independently by the unit’s controller, in order to minimize the absorbed energy whatever the cooling and/or heating demand might be
  • VERY HIGH EFFICIENCY
    High full load and partial load efficiency in both heating and cooling mode, using inverter technology to continuously modulate compressors operation and EC fans as standard, in order to deliver the exact amount of energy based on the actual needs of the plant. High efficiency means reduced energy consumption throughout the entire year, for any operation mode and any outdoor condition.
  • ErP READY
    The highest level of efficiency at part load, thanks to the inverter technology, can meet and exceed the minimum seasonal efficiency for heating, SCOP (only for reversible units) and for cooling, SEER, according with the eco-sustainable design requirements for all products using energy. The units already comply with the minimum seasonal energy efficiency requirements that will start from 2021.
  • WIDE OPERATING RANGE
    Unit´s operation guaranteed with external air temperature down to -12°C during winter and up to 46°C during summer. Production of hot water up to 60°C without accessories and chilled water from -8°C to +18°C in order to suit any possible application.
  • HARMONY BETWEEN UNIT AND PLANT
    Low inrush current and power factor higher than similar fixed speed units, permit an easy electrical installation which is not stressed during start-up and with no need of extra devices for power factor correction. The use of VSD technology allows the unit to partialize in a stepless way, with consequent lower fluctuations of leaving water temperature.
  • TRUE SILENCE
    At partial loads (ie for most of the year), thanks to the use of EC fans and VSD screw compressors, i-FX-Q2 units are characterized by lower noise emissions compared to fixed speed units.
  • FLEXIBLE SELECTION
    The units can be selected beyond the nominal point, giving the possibility to contain the initial investment (boost selection) or to enphasize even more the efficiencies (derating selection).

Accessories

  • “LT” kit for working down to -12°C in heat pump mode
  • Noise reducer (only on not silenced versions)
  • Special fan diffusers
  • Thicker soundproofing cladding
  • Hydronic group
  • VPF (Variable Primary Flow) system
  • Set-up for remote connectivity with ModBus, Echelon, Bacnet, Bacnet over-IP.
  • Touch Screen visual display
  • Leak detector