TFV2
Model TFV2 is an Induction Chilled Beam for exposed mounting
on the ceiling or suspended in all applications where there is
no false ceiling. It is supplied with our patented system to chan-
ge the air inlet flow direction without reducing performance.
Each unit is also fitted with a new, integrated air flow rate
adjustment system (optional).

Categories: , Tag:

TFV2
Model TFV2 is an Induction Chilled Beam for exposed mounting
on the ceiling or suspended in all applications where there is
no false ceiling. It is supplied with our patented system to chan-
ge the air inlet flow direction without reducing performance.
Each unit is also fitted with a new, integrated air flow rate
adjustment system (optional).
The TFV2 model chilled beam has been designed to offer win-
ning solutions in all phases of the design, manufacture and
operational usage of the air conditioning plant.
In particular it has the following benefits:
•Developed with the aid of Computational Fluid Dynamics pro-
grams to optimize induction and capacity of the unit.
•The exposed portion (micro-perforated under panel and side
profiles) can be made in any length regardless of the length of
the active part (upper heat exchange element).
•Controllable Inlet Air flow direction without loss of performan-
ce (Roccheggiani patent).
•On-site adjustable Air Flow (optional).
•Integrated anti-drip system (only for some models).
•Virtually silent operation.
•2 pipe or 4 pipe water cooling and heating options.
•Easy access for cleaning and inspection of the beam surfa-
ces and fittings.
•Available options for valve integration, anti-condensation
sensor, air extraction damper.
•Air and water pass-through version to serve deeper rooms
with a modular installation.

4-pipe Cooling/Heating solution
The appliance is also available in a 4 pipe option with a circuit
dedicated to heating.
It is possible to achieve effective heating with low levels of ver-
tical temperature stratification in buildings complying with the
latest energy standards, with no heat dispersion from the floor
and typical floor to ceiling heights of between 2.7-3.0 m.
Heating is also possible with the 2-pipe version where the per-
formance is further enhanced so even lower heated water tem-
peratures can be used.

Incorporated anti-condensation sensor
The beam can be supplied with an optional anti-condensation
sensor.
This sensor is located on the coil battery, in the optimal po-
sition where it is constantly in contact with the room air and
therefore able to react quickly whenever condensation occurs.

Integrated regulating valves and actuators
The beam can be supplied with control kits (valve + electro-
thermal actuator) for both the 2 pipe & 4 pipe solutions.
The valves can be accessed through the openable lower panel.

Integrated air flow regulation system
The beam can be supplied with an integrated system to modify
the geometry of the nozzles hence modifying airflow on the
beam at the same working pressure level.